Project

General

Profile

Actions

action #18700

closed

openQA worker doesn't work reliable anymore after needle created in interactive mode and reloaded

Added by zluo almost 7 years ago. Updated over 6 years ago.

Status:
Closed
Priority:
Normal
Assignee:
-
Category:
Regressions/Crashes
Target version:
-
Start date:
2017-04-21
Due date:
% Done:

0%

Estimated time:

Description

Problem

Test running in interactive mode
Create one needle and reload the needle to continue
After this step the openQA worker is not able to detect existing needle anymore and the test fails therefore after needle cannot be matched.

Restart openQA worker and it works without any problem till creating a new needle.

example: yast2_control_center at: http://e13.suse.de/tests/2688

create needle yast2_control-center-partitioner and reload it to continue, but then following tests Services Manager failed. It shows selected item only. Please check the logs there.


Related issues 5 (0 open5 closed)

Related to openQA Project - action #18880: fix interactive mode with cachingClosed2017-04-29

Actions
Related to openQA Project - action #18364: interactive mode - needle editor - reload needles and retry doesn't work on most casesClosed2017-04-05

Actions
Related to openQA Project - action #18384: interactive mode - needle editor - save a new needle doesn't work in most casesClosed2017-04-06

Actions
Related to openQA Project - action #17786: [tools]NFS-less mode: Interactive mode needs to resync needlesClosed2017-03-19

Actions
Is duplicate of openQA Project - coordination #14818: [EPIC] Interactive mode is an usability disasterResolvedmkittler2018-05-23

Actions
Actions #1

Updated by okurz almost 7 years ago

  • Related to action #18880: fix interactive mode with caching added
Actions #2

Updated by okurz almost 7 years ago

  • Related to action #18364: interactive mode - needle editor - reload needles and retry doesn't work on most cases added
Actions #3

Updated by okurz almost 7 years ago

  • Related to action #18384: interactive mode - needle editor - save a new needle doesn't work in most cases added
Actions #4

Updated by okurz almost 7 years ago

Actions #5

Updated by okurz almost 7 years ago

  • Category set to Regressions/Crashes
  • Priority changed from Normal to Low

As long as it is not reproducible we can not do so much about it but the interactive mode is not in a very good shape anymore. I linked related issues.

Actions #6

Updated by okurz almost 7 years ago

  • Blocked by action #17786: [tools]NFS-less mode: Interactive mode needs to resync needles added
Actions #7

Updated by okurz almost 7 years ago

  • Priority changed from Low to Normal

At least I could reproduce that the interactive mode on o3 and osd with caching is not working to reload needles.

Actions #8

Updated by coolo over 6 years ago

  • Blocked by deleted (action #17786: [tools]NFS-less mode: Interactive mode needs to resync needles)
Actions #9

Updated by coolo over 6 years ago

  • Related to action #17786: [tools]NFS-less mode: Interactive mode needs to resync needles added
Actions #10

Updated by coolo over 6 years ago

Actions #11

Updated by coolo over 6 years ago

Actions #12

Updated by coolo over 6 years ago

  • Status changed from New to Closed

refusing to work on old interactive mode

Actions

Also available in: Atom PDF