Project

General

Profile

Actions

action #119059

closed

Use qa-power8 for ppc tests in o3 - network connected?

Added by okurz over 1 year ago. Updated 3 months ago.

Status:
Rejected
Priority:
Low
Assignee:
Category:
-
Target version:
Start date:
Due date:
% Done:

0%

Estimated time:
Tags:

Description

Motivation

The machine "power8" is currently not available for o3 meaning there is currently no ppc testing in o3 at all. Use the existing machine qa-power8 for o3 ppc testing

Acceptance criteria

  • AC0: We know what kind of setup we need (baremetal vs. HMC managed, e.g. ask test maintainers)
  • AC1: At least one ppc openQA test from openqa.opensuse.org passed after running on qa-power8 (reduced schedule is ok)

Suggestions

  • DONE: Find out BMC details -> covered with https://gitlab.suse.de/qa-sle/qanet-configs/-/merge_requests/43
  • Power on the machine over BMC https://qa-power8.qa.suse.de
  • Ensure there is a physical network connection as according to https://progress.opensuse.org/issues/119059 there is currently no ethernet connection for the guest system
  • Follow-up with suggestions from #119059#note-47
    1. Physically connect keyboard+display(or serial)+storage to the machine, install Linux and enable remote IPMI
    2. Connect back to HMC, install VM and try to enable remote ipmi to the bare-metal machine and then set back to OPAL and continue with bare-metal Linux installation (preferred by cdywan, sriedel, nicksinger)
    3. Follow up with the discussions with IBM in bugzilla to find out what is the right way to install remote controlled bare-metal in OPAL mode (preferred by mkittler, okurz)
    4. As discussed in #119059#note-43 as alternative: we could continue with the HMC mode. This would likely mean setting up an HMC within the o3 network (or making HMC 3 somehow accessible).
  • Try to login over ssh or virt-manager or reinstall in case there is no or no usable OS on it
  • Install openQA-worker on the machine
  • Create SUSE-IT EngInfra ticket to move the machine's ethernet interface based on racktables information to the o3 network (VLAN 662)
  • Add according networking information on o3 into /etc/dnsmasq.d/openqa.conf
  • Configure the machine OS for dhcp client mode and ensure the machine gets an address from o3 dnsmasq
  • Ensure the system is able to execute openQA tests from o3

Related issues 4 (2 open2 closed)

Related to openQA Infrastructure - action #122302: Support SD-105827 "PowerPC often fails to boot from network with 'error: time out opening'"Resolvednicksinger2022-12-212023-02-02

Actions
Copied to openQA Infrastructure - action #119755: Use a PowerVM machine to serve both PowerVM LPARs for testing as well as one VM running qemu testsNew2022-11-02

Actions
Copied to openQA Infrastructure - action #123712: PowerVM HMC within o3, e.g. on VMNew2023-01-26

Actions
Copied to openQA Infrastructure - action #125216: Use qa-power8 for ppc tests in o3 - try one of the suggestions size:MResolvedokurz2023-03-01

Actions
Actions

Also available in: Atom PDF