Actions
action #15396
closedopenQA Project (public) - action #15378: ppc worker died somewhere in the middle
malbec unusable (see parent ticket)
Start date:
2016-12-08
Due date:
% Done:
0%
Estimated time:
Difficulty:
Updated by okurz about 8 years ago
- Project changed from openQA Project (public) to openQA Tests (public)
- Category changed from 168 to Infrastructure
Updated by mgriessmeier about 8 years ago
- Status changed from New to Feedback
Well... it seems every problem with malbec gets solved by applying dinar's custom firmware after a qemu update...
All I did was
malbec:~ # cp ./new_slof_maybe.bin /usr/share/qemu/slof.bin
I'll try to convert this into a salt recipe somehow...
Though we need to think about a better way of doing this (It can't be that the upstream version of qemu is not working for us... - But that's none of my business)
Updated by okurz about 8 years ago
- Assignee set to mgriessmeier
So who did the update then and missed this part?
mgriessmeier wrote:
I'll try to convert this into a salt recipe somehow...
please do so. That is #12350 then
Updated by okurz about 8 years ago
- Related to action #12350: [tools]version of os-autoinst on malbec+overdrive2 should be same as other workers (using salt) (was: looks like old version) added
Updated by mgriessmeier about 8 years ago
- Status changed from Feedback to Resolved
fixed by adding malbec to salt which is always copying the custom firmware for qemu-ppc
Actions