action #90707
closed[Timebox:8h] investigate sporadic failure in shutdown
0%
Description
This failure happened twice recently in this specific test. It may happen as well in other places. Could be that the key ctrl-alt-del is not received by SUT, or that the logout dialog appeared after timeout (15 secs, unlikely).
openQA test in scenario sle-15-SP3-Full-ppc64le-offline_install+skip_registration@ppc64le fails in
shutdown
Test suite description¶
Maintainer: riafarov
Offline installation. Skipping registration for SLE 15, as requires network connection. This is default behavior for SLE 12.
Reproducible¶
Fails since (at least) Build 171.1 (current job)
Expected result¶
Last good: 168.1 (or more recent)
Further details¶
Always latest result in this scenario: latest
Updated by JRivrain about 3 years ago
- Project changed from openQA Tests to qe-yam
Updated by riafarov about 3 years ago
Recent failure: https://openqa.suse.de/tests/5839618
Updated by JERiveraMoya about 3 years ago
- Status changed from Workable to In Progress
Updated by JERiveraMoya about 3 years ago
It is really sporadic, sometimes I got 20 out 20 successful runs. Other times this There are different issues and we have bugs for each one:
- xterm failure is known bug
- shutdown failure opening logout dialog is pointing in the code to an old bug, there is a hard and soft failure for it.
- machine not shutting down in 60 seconds there is another know bug -> I don't see the point to increase timeout here, as it is already marked in the code with the bug plus this functionality is used in many placed, it would worth it if this particular failure would happen more often, but for now it is a combination of the three described above.
Updated by JERiveraMoya about 3 years ago
- Status changed from In Progress to Feedback
Updated by JERiveraMoya about 3 years ago
- Status changed from Feedback to Closed