Project

General

Profile

Actions

action #88189

closed

Firmware upgrade of qa-power8-4.qa.suse.de

Added by nicksinger over 3 years ago. Updated almost 3 years ago.

Status:
Rejected
Priority:
Normal
Assignee:
Category:
-
Target version:
Start date:
2021-01-25
Due date:
% Done:

0%

Estimated time:

Description

Motivation

We were told that we need to apply the most recent firmware on machines which might help with some problems

I upgraded qa-power8-4 to the newest firmware version available at Fix-Central. The machine is according to /proc/cpuid a 8348-21C-machine. I Flashed the hpm package according to the docs https://delivery04.dhe.ibm.com/sar/CMA/SFA/08ct3/0/8348_820.1923.20190613n.html#__RefHeading___Toc1210_1053759979 (See section 7.2). Afterwards I boot up the system again just to see:

5.83228|System shutting down with error status 0x90FF0003

Several resets of the system and BMC I don't see any message anymore. The webinterface reports errors with the "sensors" "OCC Active", "Boot Count" and "BIOS Golden Side".

Actions

Also available in: Atom PDF