action #64800
closed
The worker openqaworker9.suse.de is down
Added by Xiaojing_liu about 4 years ago.
Updated about 4 years ago.
Description
The OSD deployment failed at 2020-03-25. The fail reason is that openqaworker9.suse.de is down.
The command ipmitool ... power status
shows that 'Error: Unable to establish IPMI v2 / RMCP+ session' .
The solution is:
- Create a ticket in http://infra.nue.suse.com/
- remove openqaworker9 from the salt keys on OSD by using
salt-key -d openqaworker9.suse.de
- restart OSD deployment.
- Due date set to 2020-04-13
- Status changed from New to Blocked
- Assignee set to Xiaojing_liu
alright so please track the ticket as "Blocked" as you will be notified about updates in the infra ticket. I am setting a "due date" so that you will also receive a reminder from progress to crosscheck if you have not received an update from SUSE IT within that timeframe.
- Status changed from Blocked to Resolved
ticket was resolved, machine was back up. It was immediately executing some jobs but that caused some problems because the worker was not up-to-date. I manually installed package updates and rebooted after kernel upgrades. Then I applied salt high state from osd and I checked that tests executed fine.