Project

General

Profile

Actions

action #58945

closed

OpenQA worker service not restarted after OpenQA update

Added by MDoucha over 4 years ago. Updated over 4 years ago.

Status:
Resolved
Priority:
Normal
Assignee:
Category:
-
Start date:
2019-10-31
Due date:
% Done:

0%

Estimated time:

Description

The openqa-worker service on some openqa.suse.de workers doesn't get restarted after update. This may cause version mismatch between os-autoinst and openQA-common packages.

One example of this mismatch are these three verification runs for https://github.com/os-autoinst/os-autoinst-distri-opensuse/pull/8329 below:
openqaworker2: https://openqa.suse.de/tests/3541705 (openqa-worker service last restarted on 2019-10-30)
openqaworker6: https://openqa.suse.de/tests/3541697 (openqa-worker service last restarted on 2019-09-18)
openqaworker9: https://openqa.suse.de/tests/3544337 (openqa-worker service last restarted on 2019-09-18)

All three jobs ran the same test modules (see autoinst log) but all tests after intall_ltp were scheduled at runtime. Updating test schedule at runtime requires patches merged into OpenQA on 2019-09-27 so openqaworker6 and openqaworker9 didn't update test schedule due to still running openQA-common from mid-September, before the patches were merged.