Project

General

Profile

Actions

action #69694

closed

openqa-worker systemd services running in osd which should not be enabled at all and have no tap-device configured auto_review:"backend died:.*tap.*is not connected to bridge.*br1":retry

Added by okurz over 4 years ago. Updated over 4 years ago.

Status:
Resolved
Priority:
Normal
Assignee:
Category:
-
Start date:
2020-08-07
Due date:
2020-09-01
% Done:

0%

Estimated time:

Description

Observation

https://openqa.suse.de/tests/4535923 is incomplete with proper reason "backend died: 'tap14' is not connected to bridge 'br1' at /usr/lib/os-autoinst/backend/qemu.pm line 149." as introduced in #66376 but the worker instance openqaworker3:15 should not be running at all

Workaround

Restart the job until it ends up on a properly configured worker instance


Related issues 2 (0 open2 closed)

Related to openQA Project (public) - action #66376: MM tests fail in obscure way when tap device is not presentResolvedokurz2020-05-04

Actions
Related to openQA Project (public) - coordination #65118: [epic] multimachine test fails with symptoms "websocket refusing connection" and other unclear reasonsResolvedokurz2020-04-012020-09-30

Actions
Actions

Also available in: Atom PDF