[qam] test fails in rrdtool_x11 - mouse visible in screen

Added by szarate almost 5 years ago. Updated almost 5 years ago.

Status:
Resolved
Priority:
Normal
Assignee:
Category:
Bugs in existing tests
Target version:
-
Start date:
2019-05-16
Due date:
% Done:

100%

Estimated time:
Difficulty:

Description

Observation

openQA test in scenario sle-15-SP1-Installer-DVD-x86_64-extra_tests_on_gnome@svirt-xen-hvm fails in
rrdtool_x11

Test suite description

Maintainer: asmorodskyi, okurz. Extra tests which were designed to run on gnome

Suggestion

the rrdtool_x11 module fails due to a problem with the needle matchin on xen backend, I suggest simply hiding the mouse in the test code.

Reproducible

Fails since (at least) Build 227.1 (current job)

Expected result

Last good: 225.1 (or more recent)

Further details

Always latest result in this scenario: latest

Actions #1

Updated by szarate almost 5 years ago

https://openqa.suse.de/tests/2896776 also failed to match but without mouse. I suggest that the needle might match the graph part without the data on the x or y axis, to avoid more problems (as the only thing that moved, are the numbers)

Actions #2

Updated by martinsmac almost 5 years ago

I suspect that needles correction not merged with rrdtool. I changed some areas to certify only graph without numbers, let me check this

Actions #3

Updated by martinsmac almost 5 years ago

  • Status changed from New to In Progress

ok, I told with Josef, and I will review all needles on this, to like this:
http://10.161.229.197/tests/613#step/rrdtool_x11/48

Thank you.

Actions #4

Updated by martinsmac almost 5 years ago

  • Status changed from In Progress to Resolved
  • % Done changed from 0 to 100
Actions