Project

General

Profile

Actions

action #103305

closed

Product is not selected due to dialog appears earlier in ssh-X test suite in ppc64le

Added by JERiveraMoya about 3 years ago. Updated almost 3 years ago.

Status:
Closed
Priority:
High
Assignee:
Target version:
Start date:
2021-11-30
Due date:
% Done:

0%

Estimated time:

Description

Observation

openQA test in scenario sle-15-SP4-Online-ppc64le-ssh-X@ppc64le-hmc-single-disk fails in
welcome

We are not able to select the radiobutton because some needle match while the popup appears
trying to select radiobutton but the event reach the wrong screen landing in the popup.
We should try to make it more stable without affecting other scenarios.

Actions #1

Updated by JERiveraMoya about 3 years ago

  • Tags set to qe-yast-refinement
  • Project changed from openQA Tests (public) to qe-yam
  • Category deleted (Bugs in existing tests)
  • Target version set to Current
Actions #2

Updated by JERiveraMoya about 3 years ago

  • Priority changed from Normal to High
Actions #3

Updated by JERiveraMoya about 3 years ago

  • Description updated (diff)
Actions #4

Updated by JERiveraMoya about 3 years ago

  • Description updated (diff)
Actions #5

Updated by openqa_review almost 3 years ago

This is an autogenerated message for openQA integration by the openqa_review script:

This bug is still referenced in a failing openQA test: ssh-X@ppc64le-hmc-single-disk
https://openqa.suse.de/tests/7887156

To prevent further reminder comments one of the following options should be followed:

  1. The test scenario is fixed by applying the bug fix to the tested product or the test is adjusted
  2. The openQA job group is moved to "Released" or "EOL" (End-of-Life)
  3. The bugref in the openQA scenario is removed or replaced, e.g. label:wontfix:boo1234
Actions #6

Updated by JERiveraMoya almost 3 years ago

  • Tags deleted (qe-yast-refinement)
  • Status changed from New to Workable
Actions #7

Updated by JERiveraMoya almost 3 years ago

  • Status changed from Workable to In Progress
  • Assignee set to JERiveraMoya
Actions #8

Updated by JERiveraMoya almost 3 years ago

  • Status changed from In Progress to Closed

The event of radiobutton selection is lost due to the problems with the ssh-x for this virtualization environment.
It almost impossible to workaround, I tried to increase timeout and click using the shortcut instead of the mouse but the effect is the same.
Job labeled with https://bugzilla.suse.com/show_bug.cgi?id=1178172 and I comment in this known bug for status.

Actions

Also available in: Atom PDF