## Observation 

 [Alerting] QA-Power8-4-kvm: Disk I/O time alert 

 Metric name sdj 
 Value 26600.000 

 http://stats.openqa-monitor.qa.suse.de/d/WDQA-Power8-4-kvm/worker-dashboard-qa-power8-4-kvm?tab=alert&viewPanel=56720&orgId=1 

 ## Problem 
 We just recently in #110269 worked on Disk I/O time alerts, also on QA-Power8-4-kvm. Either we need to relax values even more, or there is a real hardware problem or we need to find different solutions, e.g. longer pending time. 

 ## Acceptance criteria 
 * **AC1:** No more alerts 

 ## Suggestions 
 * Check that there are no actual hardware issues e.g. using smartctl, do what https://progress.opensuse.org/issues/110269#note-12 says 
 * Bump the values again 
 * Why do we monitor the disk sdj? the machine seems to have only two real physical devices, sda and sdb. `journalctl | grep sdj` reports: 
    
     ``` 
 May 22 03:33:08 QA-Power8-4-kvm kernel: sd 7:0:0:3: [sdj] Attached SCSI removable disk 
 May 29 03:33:08 QA-Power8-4-kvm kernel: sd 7:0:0:3: [sdj] Attached SCSI removable disk 
 Jun 05 03:33:07 QA-Power8-4-kvm kernel: sd 8:0:0:3: [sdj] Attached SCSI removable disk 
     ``` 

 We should make sure we do not care about such devices or do not even have these. The devices always show up during boot. 
 * Take a look what was done in https://gitlab.suse.de/openqa/salt-states-openqa/-/merge_requests/682 to ignore certain devices, also see https://github.com/influxdata/telegraf/tree/master/plugins/inputs/diskio for options